The 110WX gives wind, air temperature, and barometric pressure readings. Feature-rich and encased in a durable, rugged housing that is IPX6 rated. Reliability and performance, along with no moving parts, makes the 110WX a trouble-free and affordable choice.
Features
- Ultrasonic measurement of apparent wind speed and direction
- Barometric pressure
- Air temperature
- Housing IPX6 rated for water-ingress protection
- NMEA 0183/ASCII serial data protocol over RS-232 interface
- NMEA 2000 protocol over CAN
Order 000-11740-001 Cable separately
Specifications
Wind Speed:
- Range: 0 to 40 m/s
- Accuracy: 5% at 10 m/s at 4 angles
- Resolution: 0.1 m/s
- Calculations: User configurable damping
Wind Direction:
- Range: 0° to 359.9°
- Accuracy: ±3° at 10 m/s
- Resolution: 0.1°
- Calculations: User configurable damping
Air Temperature:
- Range: -40° to 80°C (-40 to 176°F)
- Accuracy: ±0.3°C at 20°C
- Resolution: 0.1°C
Barometric Pressure:
- Range: 300 to 1100 hPa
- Accuracy: ±0.5 hPa at 25°C (or better)
- Resolution: 0.1 hPa
Optional Relative Humidity:
- Range: 0 to 100% RH
- Accuracy: ±5% RH at 0 to 90% RH at 20°C
- Resolution: 0.1% RH
Operating Temperature Range: -25 to 55°C (-13 to 131°F)
Power:
- Supply Voltage: 9 to 40 VDC
- Supply Current: <55 mA (<0.7 W) at 12 VDC
- NMEA 2000® Load Equivalency Number (LEN): 2
Communications:
- Available Interface: Serial RS-232, Serial RS-422, CAN
- Available Protocol: Comma delimited ASCII, NMEA 0183, NMEA 2000
- Serial Output Rate: 1 Hz typical. User selectable. 10 Hz maximum recommended
- Mounting-thread Size on Base: Standard 1"-14 UNS (3/4" NPT optional)
- Certifications and Standards: CE, IPX6 (IPX4 with optional Relative Humidity sensor), RoHS, IEC61000-4-2, IEC60945, IEC60950_1C, IEC60950_22A, EN55022, EN55024, EN14982