- Out-of-Stock
AP44 Autopilot Controller
AP44 Autopilot Controller - Compact and easy to use, the AP44 is your main control panel for the Autopilot. Rotary dial and key function buttons gives you what you need to steer the vessel in a compact unit.
NAC-3 Autopilot Core Pack - Comes with NAC-3 Autopilot Computer, Precision-9 Compass and RF-25N Rudder Feedback unit.
The NAC-3 Autopilot Computer is the brains behind your autopilot system. NAC-3 contains the control algorithms developed to helm a yacht across a broad range of weather conditions and sea-states, alongside the electronics needed to operate a hydraulic or mechanical drive unit, while also interfacing with other components including heading sensors and rudder feedback units. The NAC-3 was designed for boats 10 metres (33 feet) or greater in length and is rated to operate high-current hydraulic drives, mechanical drive units, and solenoid valves with a current rating of 30 Amps continuous (50 Amps peak).
*Lowrance compatibility is limited to HDS LIVE only.
Temperature, operation | 0 to +55°C |
Temperature, storage | -32 to +70°C |
Protection | IPx7 |
Weight in Kg | 0.7kg, 1.6lbs |
Dimmension Max size, mm (length x width x height) | 211x196x65.5mm, 8.31"x7,72"x2.58" |
Mounting | Bulkhead |
Construction | Plastic |
Color | Black |
Cable inlet | Grommet (Spare Incl) |
Local supply | 12/24 V DC +10-30% |
NMEA 2000 Load Equivalent number (50mA) | 1 |
Interface | |
Reversible motor control of rudder | Max continious load 30A, peak 50A for 1s |
On/off solenoid control of rudder | 12/24V DC, common, load range 10mA to 10A, off current <1mA |
Engage output for bypass/clutch | 12/24V DC, min 10mA, max 3A |
Rudder angle, frequency input | 15V, 1.4 to 5kHz, resol. 20Hz/° OR NMEA2000 |
NFU port/stbd input and mode indicator output | External open/close contact, common ret, contact current max 30mA |
Mode input | External open/close or pulse contact for SYSTEM SELECT, common ret, close to activate, contact current max 30mA |
External alarm output for buzzer/relay | Max 100mA, voltage level as local supply |
IEC 61162-1 input (NMEA0183 In) | 1 ch |
IEC 61162-1 output (NMEA0183 Out) | 1 ch |
IEC 61162-1 speed | 4.8 & 38.4 kbaud |
NMEA2000 | Certified (pending) |